Shaher, H., Eltabey, M., Abu elnasr, H., Abdelbaki, S., Soliman, T. (2023). Handmade Needleless Midurethral Sling In Comparison With Transobturator Tension-Free Vaginal Tape In Treatment Of Genuine Female Stress Urinary Incontinence. Benha Medical Journal, 40(Annual conference issue), 158-173. doi: 10.21608/bmfj.2023.183836.1741
Hussein Shaher; Magdy Eltabey; Hosam Abdel Fatah Abu elnasr; Shabieb A. Abdelbaki; Tarek Soliman. "Handmade Needleless Midurethral Sling In Comparison With Transobturator Tension-Free Vaginal Tape In Treatment Of Genuine Female Stress Urinary Incontinence". Benha Medical Journal, 40, Annual conference issue, 2023, 158-173. doi: 10.21608/bmfj.2023.183836.1741
Shaher, H., Eltabey, M., Abu elnasr, H., Abdelbaki, S., Soliman, T. (2023). 'Handmade Needleless Midurethral Sling In Comparison With Transobturator Tension-Free Vaginal Tape In Treatment Of Genuine Female Stress Urinary Incontinence', Benha Medical Journal, 40(Annual conference issue), pp. 158-173. doi: 10.21608/bmfj.2023.183836.1741
Shaher, H., Eltabey, M., Abu elnasr, H., Abdelbaki, S., Soliman, T. Handmade Needleless Midurethral Sling In Comparison With Transobturator Tension-Free Vaginal Tape In Treatment Of Genuine Female Stress Urinary Incontinence. Benha Medical Journal, 2023; 40(Annual conference issue): 158-173. doi: 10.21608/bmfj.2023.183836.1741
Handmade Needleless Midurethral Sling In Comparison With Transobturator Tension-Free Vaginal Tape In Treatment Of Genuine Female Stress Urinary Incontinence
3Urology department ,benha faculty of medicine,benha university,benha,egypt
4Urology department, Faculty of Medicine, Benha University, Egypt
Abstract
Backgrouds: Stress urinary incontinence is a widely experienced condition among females. Our aim was to compare TOT and handmade needleless midurethral sling regarding safety and effectiveness for management of genuine stress urinary incontinence in females. Methods: Sixty female cases with genuine SUI randomly allocated to 2 groups: Group I: 30 patients were operated on using handmade needleless mid urethral sling (Prolene, Ethicon, USA) mesh 15 x15 cm by cutting 134 mm x 20 mm tape). Group II: 30 patients were using TOT (Obtryx transobturator sling system, Boston Scientific, USA) “outside-in” technique. Post-operative evaluation at 3, 6 and 12 months by cough stress test, post-voiding residual urine and uroflowmetry, a negative cough stress test with absence of urine leakage indicated cure. Results: Group I demonstrated a shorter Operative time than group II 14.17±2.82 min and 25.23±2.63 min respectively (P value